Sealant Yield (Linear Metres Sealant per Unit)

  JOINT DIMENSION PACKAGING FORMAT
Width
mm
 
Depth
mm
 
300 mL   600 mL   858 mL   5.7 L   11.4 L  
      6     
6 7.4 
14.8 
21.2 
141.3 
282.7 
13 6 3.7
7.4
10.6
70.7
141.4
13 13 1.9 3.7
5.3
35.3
70.7
19 6 2.5 5.0
7.1
47.3
94.6
19 13 1.3 2.5 3.6 23.8
47.5
19
19 0.8 1.7 2.4 16.0 31.9
25 6 1.9 3.7 5.3 35.3 70.7
25 13 0.9 1.9 2.7 17.7 35.3
25 19 0.6 1.3 1.8 12.0 23.9
25 25 0.5 1.0 1.4 9.1 18.2
32 6 1.5 3.0 4.3 28.5 57.0
32 13 0.8 1.5 2.2 14.3 28.5
32 19 0.5 1.0 1.5 9.7 19.4
32 25 0.4 0.7 1.0 6.8 13.7
32 32 0.3 0.6 0.9 5.7 11.4
38 6 1.3 2.5 3.6 23.8 47.5
38 13 0.6 1.3 1.8 12.0 23.9
38 19 0.4 0.8 1.2 8.0 16.0

1 metre = 3.28084 ft

Note: The above charts are a theoretical guide only. Allowances must be made for surface profile, wastage, etc.

Mortar Consumption

 

Coverage per mm thickness =


 
Yield (L) / Applied Thickness (mm)
 

Water and Solvent-Based Coatings Consumption

L/m2 =


Coverage per pail (m2) = Pail volume (L) * coverage rate (m2/L)


Wet Film Thickness (mils) = 40 / Coverage rate (m2/L)


Dry Film Thickness (mils) = Wet film Thickness * (Volume Solids/100)

 

Mortar Yield and Coverage (L and m2)