Sika Boom®-121 Insulation
Sika Boom®-121 Insulation is a one-component, polyurethane spray foam that provides thermal and sound insulation.
- 20 board feet coverage
- R value of 5,66 (per inch).
- Excellent thermal insulation value (0.025 W/(m.K).
- Excellent adhesion to many building materials.
- May be applied at temperatures between +5 °C and 30 °C.
- Yield up to 3 m² with 1.5 cm thickness for one layer if applied from a distance of ~40 cm with normal application speed.
- Paintable.
- Does not contain any propellant gases.
Usage
- Rim joist sealer.
- Roofs, attics, basements, interior walls, interfloor overlapping.
- Air sealing and insulating.
- Elimination of thermal bridges.
Advantages
- 20 board feet coverage
- R value of 5,66 (per inch).
- Excellent thermal insulation value (0.025 W/(m.K).
- Excellent adhesion to many building materials.
- May be applied at temperatures between +5 °C and 30 °C.
- Yield up to 3 m² with 1.5 cm thickness for one layer if applied from a distance of ~40 cm with normal application speed.
- Paintable.
- Does not contain any propellant gases.
Packaging
Net weight: 807 mL (775 g) can / 12 cans per case
Colour
Light yellow
Product Details
Shelf Life
18 months from the date of production, if it is stored properly in undamaged, original, sealed packaging and if storage conditions are met.
Storage Conditions
Product must be stored in an upright position, in dry conditions, protected from direct sunlight and at temperatures between 5 °C and 25 °C.
Density
| 15±1 kg/m3 | ASTM D1622 |
Compressive Strength
| 0,03 MPa | DIN 53421 |
Thermal Conductivity
| 0,025 W/m.K (at 20°C) | DIN 52612 |
Service Temperature
-40 to 80 °C
Resistance to UV Exposure
- Cured foam will discolor if exposed to ultraviolet light.
- Paint or coat the cured foam for best results in outdoor applications
Resistance to Fire
| B3 class of cured foam | DIN 4102-1 |
Application
Layer Thickness
- Can be applied at any desired thickness as long as it is applied layer by layer. The thicker, the higher insulation value.
- For an effective insulation value, the recommended application thickness is 5 cm (R 5,66) and should be reached to this thickness with minimum 3 layers. It is not possible to get the ideal insulation value with 1 or 2 layers.
Dew Point
Elimination of the dew point
Curing Time
Full cure: 24 hours
| Tack-Free time: 4 min | ASTM C1620 |
Consumption
Yield up to 3 m² with 1.5 cm thickness for one layer if applied from a distance of ~40 cm with normal application speed.
20 board feet
Yield
3 m² for 1,5 cm thickness
SUBSTRATE PREPARATION
The substrate must be clean, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed. Sika Boom®-121 Insulation adheres without primers and/or activators.
MIXING
Shake Sika Boom®-121 Insulation can well for about 60 seconds before use. Turn the Sika Boom®-121 Insulation can upside down and screw the straw adapter firmly into place without pressing the valve.
Turn red applicator tip to desired position.
APPLICATION
Apply for 5 seconds with a 2-second pause in between applications (Applying product for more than 5 seconds at a time might produce some leakadge from the valve or straw connectors).
Regulate the foam flow by applying more or less pressure on the valve/adapter. Sika Boom®-121 Insulation can only be used in the upside down position, failure to invert the can will prevent the foam from dispensing properly. Take care to allow each layer to cure and expand sufficiently before applying additional layers.
- Spray the foam 30-45 cm distance from the wall for vertical applications.
- Spray the foam 15-20 cm distance from the ceiling for horizontal applications
CLEAN UP