Sarnafil® S 327-60 Textured
Sarnafil® S 327-60 Textured Roof Membrane is a PVC thermoplastic membrane produced with an integral polyester reinforcement for high strength, with heat-weldable seams, and a textured surface.
- Embossed surface
- Excellent tear strength resistance
- Hot-air welded seams for long-term performance
- Superior fire resistance
- Proven membrane performance
Usage
Sarnafil® S 327-60 Textured is used in mechanically attached applications with various fastening methods, over various substrates. Areas of Application- New Roofs
- Reroofs
- Recovers
Advantages
- Embossed surface
- Excellent tear strength resistance
- Hot-air welded seams for long-term performance
- Superior fire resistance
- Proven membrane performance
Packaging
1.5 mm (60 mil) Membrane
3 m x 30 m (10 ft x 100 ft) roll, 177 kg (389 lb) per roll, 8 rolls per pallet
1.5 m x 30 m (5 ft x 100 ft) roll, 89 kg (195 lb) per roll, 12 rolls per pallet
Colour
- Top: White, Grey, and Tan
- Bottom: Dark Grey
Product Details
ENVIRONMENTAL INFORMATION
- Conformity with LEED®v4 MR Credit (Option 1): Building Product Disclosure and Optimization – Environmental Product Declarations
APPROVALS / CERTIFICATES
- FM Global
- Underwriters Laboratories
- ICC Code Compliance – ESR 1157
- Miami-Dade County
- Florida Building Code
- Green Globes
- NSF/ANSI 347 : Platinum Certified
Composition / Manufacturing
High quality, PVC thermoplastic roof membrane containing ultraviolet light stabilizers, flame retardant and polyester scrim reinforcement
Reinforcing Material
Polyester
Shelf Life
Not applicable
Storage Conditions
Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability.
Top surface
Textured
Overall Thickness
1.5 mm (60 mil) 1.14 mm (45 mil) | (ASTM D751) (ASTM Type III D4434 Spec. Requirement) |
Thickness Above Scrim
Exceed 0.404 mm (16 mil) |
|
Resistance to Static Puncture
Pass 15 kg (33 lbf) | (ASTM D5602), kg (lbf) (ASTM Type III D4434 Spec. Requirement) |
Resistance to Dynamic Puncture
Pass 20 J (14.7 ft-lbf) | (ASTM D5635) (ASTM Type III D4434 Spec. Requirement) |
Tensile Strength
1356 N (305 lbf/in) 890 N (200 lbf/in) | (ASTM D751) (ASTM Type III D4434 Spec. Requirement) |
Linear Dimensional Change
-0.12 % 0.5 % | (ASTM D1204) (ASTM Type III D4434 Spec. Requirement) |
Tear Strength
213 N (48 lbf) 200 N (45 lbf) | (ASTM D1004) (ASTM Type III D4434 Spec. Requirement) |
Seam Strength
Pass 75 | (ASTM D751), % of original2 (ASTM Type III D4434 Spec. Requirement) |
2 Failure occurs through membrane rupture not seam failure.
Low Temperature Flexibility
Pass Pass | (ASTM D2136), -40 °C (-40 °F) (ASTM D4434 Type III Spec. Requirement) |
Retention of Properties after Heat Ageing
Tensile Strength, % of original: Pass Elongation, % of original: Pass Tensile Strength, % of original: 90 Elongation, % of original: 90 | (ASTM D751)
(ASTM Type III D4434 Spec. Requirement) |
Resistance to UV Exposure
10,000 h 5,000 h | (ASTM G154) (ASTM Type III D4434 Spec. Requirement) |
Cracking (7x magnification) Discoloration (by observation) Crazing (7x magnification) | None Negligible None |
Weight Change after Immersion in Water
Pass ± 3.0 % | (ASTM D570) (ASTM Type III D4434 Spec. Requirement) |
Application
APPLICATION
Sarnafil® S 327-60 Textured is rolled out onto the insulation board or acceptable substrate, flipped over in order to reveal textured side of membrane as the top surface, fastened to the roof deck with appropriate plates and fasteners, and heat‐welded together by trained operators using hot‐air welding equipment. Please consult Sika’s Specification or Applicator Handbook for detailed installation procedures.