Sikaplan® Adhered-60 EnergySmart
THERMOPLASTIC PVC ROOF MEMBRANE
Sikaplan® Adhered-60 EnergySmart is a thermoplastic PVC roof membrane designed with an integral fibreglass mat reinforcement.
- Integral fibreglass mat reinforcement for excellent dimensional stability
- Heat welded seams for strength and security
Usage
Sikaplan® Adhered-60 EnergySmart is adhered to approved substrates. Areas of Application- Adhered roof systems
- Adhered roof flashings
- New construction and reroofing
Advantages
- Integral fibreglass mat reinforcement for excellent dimensional stability
- Heat welded seams for strength and security
Packaging
1.5 mm (60 mil) Membrane
3 m x 30 m (10 ft x 100 ft) roll,158 kg (348 lb) per roll, 8 rolls per pallet
1.5 m x 30 m (5 ft x 100 ft) roll, 79 kg (174 lb) per roll, 12 rolls per pallet
Colour
- Top: White, Reflective Grey, and Tan
- Bottom: Dark Grey
Product Details
APPROVALS / CERTIFICATES
- FM Global
- Underwriters Laboratories
- Underwriters Laboratories of Canada
- ICC Code Compliance – ES 1157
- Miami-Dade County
- Florida Building Code
- California Title 24
- LEED / Green Globes
- CSA-A123.21
Recycled content
9 % Pre‐consumer, 1 % Post‐consumer
Reinforcing Material
Fibreglass
Shelf Life
Not applicable
Storage Conditions
Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability.
Overall Thickness
1.5 mm (60 mil) nominal 1.14 mm (45 mil) | (ASTM D751) (ASTM Type II D4434 Spec. Requirement) |
Thickness Above Scrim
0.6 mm (24 mil) 0.4 mm (16 mil) | (-) (ASTM Type II D4434 Spec. Requirement) |
Resistance to Static Puncture
Pass 15 kg (33 lbf) | (ASTM D5602) (ASTM Type II D4434 Spec. Requirement) |
Resistance to Dynamic Puncture
Pass 10 J (7.3 ft-lbf) | (ASTM D5635) (ASTM Type II D4434 Spec. Requirement) |
Tensile Strength
285 N (64 lbf/in) 245 N (55 lbf/in) | (ASTM D751), M.D. 1 (ASTM Type II D4434 Spec. Requirement) |
276 N (62 lbf/in) 245 N (55 lbf/in) | (ASTM D751), C.M.D.1 (ASTM Type II D4434 Spec. Requirement) |
1 M.D. = Machine Direction, C.M.D. = Cross Machine Direction.
Linear Dimensional Change
-0.02 % 0.1 % max. | (ASTM D1204) (ASTM Type II D4434 Spec. Requirement) |
Tear Strength
67 N (15 lbf) 45 N (10 lbf) | (ASTM D1004) (ASTM Type II D4434 Spec. Requirement) |
Seam Strength
Pass 75 % of original2 | (ASTM D751) (ASTM Type II D4434 Spec. Requirement) |
2 Failure occurs through membrane rupture not seam failure.
Low Temperature Flexibility
Pass Pass | (ASTM D2136), ‐40 °C (‐40 °F) (ASTM Type II D4434 Spec. Requirement) |
Retention of Properties after Heat Ageing
Tensile Strength, % of original: Pass | (ASTM D751) |
Elongation, % of original: Pass | (ASTM D751) |
Tensile Strength, % of original: 90 | (ASTM Type II D4434 Spec. Requirement) |
Elongation, % of original: 90 | (ASTM Type II D4434 Spec. Requirement) |
Resistance to UV Exposure
10,000 hours 5,000 hours | (ASTM G154) (ASTM Type II D4434 Spec. Requirement) |
Cracking (7x magnification) | None |
Discoloration (by observation) | Negligible |
Crazing (7x magnification) | None |
Weight Change after Immersion in Water
2.4 % ± 3.0 % | (ASTM D570) (ASTM Type II D4434 Spec. Requirement) |
Solar Reflectance
EnergySmart Colours | Initial Solar Reflectance1 | 3-Year Solar Reflectance1 |
EnergySmart White | 0.85 | 0.73 |
EnergySmart Tan | 0.72 | 0.652 |
EnergySmart Reflective Grey | 0.73 | 0.652 |
1 Solar Reflectance testing according to ASTM C1549.
2 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Thermal Emittance
EnergySmart Colours | Initial Thermal Emittance1 | 3-Year Thermal Emittance1 |
EnergySmart White | 0.89 | 0.89 |
EnergySmart Tan | 0.89 | 0.882 |
EnergySmart Reflective Grey | 0.89 | 0.882 |
1 Thermal Emittance testing according to ASTM C1371, Slide Method.
2 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Solar Reflectance Index
EnergySmart Colours | Initial Solar Reflectance Index | 3-Year Solar Reflectance Index |
EnergySmart White | 107 | 90 |
EnergySmart Tan | 88 | 781 |
EnergySmart Reflective Grey | 90 | 781 |
1 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with
the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Application
APPLICATION
Sikaplan® Adhered-60 EnergySmart is installed after proper preparation of the approved substrate. The membrane is unrolled into approved Sikaplan or Sarnacol adhesive in accordance with Sika’s technical requirements and then pressed into place with a minimum 45 kg (100 lb) steel roller. Sikaplan® Adhered-60 EnergySmart seams are heat‐welded together by trained operators using hot‐air welding equipment. Different Sarnacol® adhesives require different application methods. Consult Sika’s Specifications or Applicator Handbook for detailed installation procedures.