Sikaplan® Fastened-60 EnergySmart
Sikaplan® Fastened-60 EnergySmart is a thermoplastic PVC roof membrane designed with polyester scrim reinforcement.
- Highly Reflective
- Excellent tear strength resistance
- Hot-air welded seams for strength and long term performance
- Factory-applied lacquer coated to reduce dirt pick up
Usage
Sikaplan® Fastened-60 EnergySmart is mechanically-attached using various attachment components over approved substrates. Areas of Application- In‐seam disc systems
- In‐seam batten, double‐weld systems
- RhinoBond® systems
- New construction and reroofing
Advantages
- Highly Reflective
- Excellent tear strength resistance
- Hot-air welded seams for strength and long term performance
- Factory-applied lacquer coated to reduce dirt pick up
Packaging
1.5 mm (60 mil) Membrane
- 3 m x 30 m (10 ft x 100 ft) roll, 158 kg (348 lb) per roll, 8 rolls per pallet
- 1.5 m x 30 m (5 ft x 100 ft) roll, 79 kg (174 lb) per roll, 12 rolls per pallet
Colour
Top: White, Reflective Grey, and Tan
Bottom: Dark Grey
Product Details
APPROVALS / CERTIFICATES
- FM Global
- Underwriters Laboratories
- Underwriters Laboratories of Canada
- ICC Code Compliance – ESR 1157
- Miami-Dade County
- Florida Building Code
- California Title 24
- LEED / Green Globes
- CSA-A123.21
Composition / Manufacturing
PVC thermoplastic roof membrane containing ultraviolet light stabilizers, flame retardant and polyester scrim reinforcement with a unique lacquer coating on the top surface.
Recycled content
9 % Pre-consumer, 1 % Post-consumer
Reinforcing Material
Polyester
Shelf Life
Not applicable
Storage Conditions
Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are not accepted due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect the ease of membrane weldability.
Overall Thickness
1.5 mm (60 mil) nominal 1.14 mm (45 mil) | (ASTM D751) (ASTM Type III D4434 Spec. Requirement) |
Thickness Above Scrim
0.6 mm (24 mil) 0.4 mm (16 mil) | (-) (ASTM Type III D4434 Spec. Requirement) |
Resistance to Static Puncture
Pass 15 kg (33 lbf) | (ASTM D5602) (ASTM Type III D4434 Spec. Requirement) |
Resistance to Dynamic Puncture
Pass 20 J (14.7 ft-lbf) | (ASTM D5635) (ASTM Type III D4434 Spec. Requirement) |
Tensile Strength
1348 N (303 lbf) 890 N (200 lbf) | (ASTM D751), M.D.1 & C.M.D.1 (ASTM Type III D4434 Spec. Requirement) |
1M.D. = Machine Direction, 1C.M.D. = Cross Machine Direction.
Linear Dimensional Change
0.24 % 0.5 % max. | (ASTM D1204) (ASTM Type III D4434 Spec. Requirement) |
Seam Strength
Pass 75 % of original2 | (ASTM D751) (ASTM Type III D4434 Spec. Requirement) |
2 Failure occurs through membrane rupture not seam failure.
Low Temperature Flexibility
Pass Pass | (ASTM D2136), ‐40 °C (‐40 °F) (ASTM Type III D4434 Spec. Requirement) |
Retention of Properties after Heat Ageing
Tensile Strength, % of original: Pass | (ASTM D-3045) |
Elongation, % of original: Pass | (ASTM D-751) |
Tensile Strength, % of original: 90 | (ASTM Type III D4434 Spec. Requirement) |
Elongation, % of original: 90 |
Resistance to UV Exposure
10,000 h | (ASTM G154) (ASTM Type III D4434 Spec.Requirement) |
Cracking (7x magnification) | None |
Discoloration (by observation) | Negligible |
Crazing (7x magnification) | None |
Weight Change after Immersion in Water
2.5 % ± 3.0 % max. | (ASTM D570) (ASTM Type III D4434 Spec. Requirement) |
Solar Reflectance
EnergySmart Colours | Initial Solar Reflectance1 | 3-Year Solar Reflectance1 |
EnergySmart White | 0.85 | 0.75 |
EnergySmart Reflective Grey | 0.73 | 0.652 |
EnergySmart Tan | 0.72 | 0.652 |
1 Solar Reflectance testing according to ASTM C1549.
2 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Thermal Emittance
EnergySmart Colours | Initial Thermal Emittance1 | 3-Year Thermal Emittance1 |
EnergySmart White | 0.89 | 0.90 |
EnergySmart Reflective Grey | 0.89 | 0.882 |
EnergySmart Tan | 0.89 | 0.882 |
1 Thermal Emittance testing according to ASTM C1371, Slide Method.
2 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Solar Reflectance Index
EnergySmart Colours | Initial Solar Reflectance Index | 3-Year Solar Reflectance Index |
EnergySmart White | 107 | 93 |
EnergySmart Reflective Grey | 90 | 781 |
EnergySmart Tan | 88 | 781 |
1 CRRC Rapid Ratings: These are interim laboratory‐aged values that simulate weathered values. These values will be replaced with the measured three‐year aged values upon completion of the weathering process. SRI values calculated using Rapid Ratings may change once the aged rating replaces the interim rating.
Application
APPLICATION
Sikaplan® Fastened-60 EnergySmart is installed on acceptable substrates and attached to the roof deck using the approved attachment method. The membrane is heat‐welded together by trained operators using hot‐air welding equipment. Sikaplan® Fastened-60 EnergySmart can be used for flashings on Sikaplan® Fastened roof projects.