Sikaflex® Self Leveling Sealant
Sikaflex® Self Leveling Sealant is a single component, self-levelling, premium-grade polyurethane sealant with an accelerated curing capacity.
- 1-component, no mixing required
- Self-levelling, pourable
- Accelerated curing
- Permanently elastic
- High durability
- Resists aging, weathering
- Excellent adhesion
- Convenient, easy-to-use packaging
- Paintable with water-, oil- or rubber-based paints
Usage
Sikaflex® Self Leveling Sealant is used to seal horizontal expansion joints in concrete and cementitious slabs such as:- Driveways
- Garages
- Sidewalks
- Balconies
- Pavements
- Terraces
- Warehouses
- Factories
- Civil structures
- Plazas
Advantages
- 1-component, no mixing required
- Self-levelling, pourable
- Accelerated curing
- Permanently elastic
- High durability
- Resists aging, weathering
- Excellent adhesion
- Convenient, easy-to-use packaging
- Paintable with water-, oil- or rubber-based paints
Packaging
300 mL (10.1 fl. oz) moisture proof composite cartridge, 12/case
858 mL (29 fl. oz. (858 ml) moisture-proof composite cartridges, 12/case
Colour
- Grey in 300 mL (10.1 fl. oz) and 858 mL (29 fl. oz) cartridges
- Sandstone only available in 858 mL (29 fl. oz) cartridge format
Product Details
APPROVALS / CERTIFICATES
- Meets Federal Specification TT-S-00230C, Type 1, Class A
- Meets ASTM C920, Type S, Grade P, Class 25
Shelf Life
12 months in original unopened packaging
Storage Conditions
Store at temperatures between 4 °C and 35 °C (40 °F and 95 °F). Condition product to 18 °C – 24 °C (65 °F – 75 °F) before using.
Shore A Hardness
| 40 ± 5 (21 days) | (ASTM D2240) |
Tensile Strength
| 1 MPa (150 psi) (21 days) | (ASTM D412) |
Elastic Recovery
> 90 %
Movement Capability
± 25 %
Resistance to Weathering
Excellent
Service Temperature
-40 °C to +76 °C (-40 °F to +170 °F)
Adhesion in Peel
| Substrate | Peel Strength | Adhesion Loss |
| Concrete | > 30 pli | 0 % |
Tensile Stress at Specified Elongation
| 0.7 MPa at 100 % (110 psi) (21 days) | (ASTM D412) |
Application
Ambient Air Temperature
Minimum: 4 °C (40 °F) / Maximum: 38 °C (100 °F)
Substrate Temperature
Minimum: 4 °C (40 °F) / Maximum: 38 °C (100 °F)
Curing Time
Final cure: 3 to 5 days
Tack-free time
1 to 2 hours
Yield
300 mL (10.1 fl. oz) Cartridge: ~Yield in Linear Feet
| 6 mm (1/4 in) Depth | 9 mm (3/8 in) Depth | 13 mm (1/2 in) Depth | |
| Width | |||
| 6 mm (1/4 in) | 24.3 | ||
| 9 mm (3/8 in) | 16.2 | 10.8 | |
| 13 mm (1/2 in) | 12.1 | 8.1 | 6.1 |
| 19 mm (3/4 in) | 8.1 | 5.4 | 4.0 |
| 25 mm (1 in) | 3.0 | ||
| 32 mm (1-1/4 in) | 2.4 | ||
| 38 mm (1-1/2 in) | 2.0 |
858 mL (29 fl. oz) Cartridge: ~Yield in Linear Feet
| 6 mm (1/4 in) Depth | 9 mm (3/8 in) Depth | 13 mm (1/2 in) Depth | |
| Width | |||
| 6 mm (1/4 in) | 69.8 | ||
| 9 mm (3/8 in) | 46.5 | 31.0 | |
| 13 mm (1/2 in) | 34.9 | 23.3 | 17.4 |
| 19 mm (3/4 in) | 23.2 | 15.5 | 11.6 |
| 25 mm (1 in) | 8.7 | ||
| 32 mm (1-1/4 in) | 7.0 | ||
| 38 mm (1-1/2 in) | 5.8 |
SUBSTRATE QUALITY
Joint wall surfaces must be clean, structurally sound, and frost-free. Joint walls must be free of oils, grease, curing compound residues, and any other foreign matter that might prevent bond.
SUBSTRATE PREPARATION
Substrate preparation should be accomplished preferably by mechanical means. All surfaces must be clean before Sikaflex® Self Leveling Sealant application. Bond breaker tape or backer rod must be used in bottom of joint to prevent three-sided bond. Proper design is 2:1 width to depth ratio.
Note: Priming is not usually necessary. Substrates only require priming if testing indicates a need. Consult Sikaflex® Primer Product Data Sheet or Contact Sika Canada Technical Service for additional information on priming.
CLEAN UP
Uncured material can be removed from equipment and tools using Sika® Cleaning Wipes or a solvent, such as xylene. Strictly follow solvent manufacturer’s warnings and instructions for use. Cured material can only be removed manually or mechanically.
FAQ
Avoid exposure to high levels of chlorine (maximum continuous level is 5 ppm of chlorine.)
Tack-free time should be between 1 to 2 hours. And the Final cure should be between 3 to 5 days.
Since system is moisture-cured, permit sufficient exposure to air. Avoid contact with materials or surfaces impregnated with, or containing, oil, asphalt, tar, or bituminous substances. Don’t cure in the presence of uncured silicone sealants, alcohol, and other solvent cleaners.
Sikaflex® Self-Leveling Sealant can be painted over with water, oil- and rubber-based paints.
When over-coating with water-, oil- and rubber- based paints, compatibility and adhesion tests are essential.
Allow at least seven (7) days for sealant to cure under stated conditions when using Sikaflex® Self-Leveling Sealant in total water immersion situations or prior to painting.
Proper design is 2:1 width to depth ratio for movement joints.
Joint dimensions should allow for 6 mm (1/4 in) minimum and 13 mm (1/2 in) maximum depth of sealant.
For best performance Sikaflex® Self-Leveling Sealant should be applied into the joint when the joint is at the mid-point of its designed expansion and contraction. Cut plastic nozzle on cartridge to desired joint size and puncture airtight seal at base of nozzle. Place cartridge in suitable sized caulking gun, place nozzle at the bottom of the joint and apply sealant into joint slot. Work in one direction and allow sealant to steadily flow and level out as necessary. Tool as required, although minimum tooling is necessary. Joint dimensions should allow for 6 mm (1/4 in) minimum and 13 mm (1/2 in) maximum depth of sealant. Proper design is 2:1 width to depth ratio for movement joints. Always use bond breaker tape or closed cell backer rod for support on horizontal joints.
Do not apply when joint walls are wet, or damp and a moisture-vapour transmission condition exists from the substrate as this can cause bubbling within the sealant.
Priming is not usually necessary. Most substrates only require priming if testing indicates a need or where sealant will be subjected to water immersion after cure.
All joint surfaces must be clean, sound, dry and frost-free. Joint walls must be free of oils, tar, asphalt, bitumen, grease, paints, coatings, sealers, curing compound residues, and any other foreign matter that might prevent adhesion. Ideally this should be accomplished by suitable mechanical methods. Install bond breaker tape to the bottom of the joint or compressible backer rod into the joint to prevent bond to surfaces other than the joint walls.
Sikaflex® Self-Leveling Sealant is used to seal horizontal movement joints in concrete and cementitious substrates such as:
- Driveways and garage floors
- Sidewalks and pavements.
- Balcony decks.
- Civil structures.
- Terrace decks.
- Pedestrian plazas.
- Warehouse and factory floors
The application temperature should be between +4 and +38 °C (39 to 100 °F). Sealant preconditioned to approximately +21 °C (70 °F) is necessary when working at extremes of temperature.
300 mL (10.1 US fl. oz) cartridge seals 3.7 m (12 ft) of 12.7 mm (1/2 in) x 6.35 mm (1/4 in) joint.
858 mL (29 US fl. oz) cartridge seals 11 m (36 ft) of 12.7 mm (1/2 in) x 6.35 mm (1/4 in) joint.
Sikaflex® Self Leveling Sealant is 1-component, no mixing required.